Description
- Anti AC & high-frequency electrosurgical & defibrillator's interference Rich screen layout, standard, large font, trend graph, OxyCRG, ECG full lead and others Strong data storage: 720 hours trends, 10000 group NIBP, 1024 alarms events ST analysis, arrhythmia analysis, pacemaker analysis, drug analysis and calculation Audible & visual alarm available, adjustable Patient information management function
- Powerful software function to support use in NICU, ICU, OR, CCU or normal patient room Optional software upgrading based on USB Wired/wireless networking with central monitoring system, up to 64 beds in one group Built-in 3 trace thermal recorder for printing real-time and historical data Multi-language i.e. English, Spanish, Turkish. Super long life rechargeable Lithium battery upto 4 hours of working time Suitable for adult, pediatrics and neonate patients
- 7-inch 4-Parameter Vital Sign Monitor Patient Monitor 4 Standard parameters :ECG, NIBP, SpO2, RESP,Ergonomic design, portable, convenient for use 7" TFT display, configurable up to 8 waveforms, enables maximum data visibility for the most critical parameters Unique digital SPO2 technology can work accurate during motion and low perfusion Resp Chest impedance method or concentration of carbon dioxide at end of respiration Scope of chest impedance method 0 time/minute - 100 minutes/minute Precision of chest impedance method time/minute Detection scope of carbon oxygen at end of respiration 3mmHg-75mmHg; 0.4%vol-9.9%vol Detection scope of respiration rate: 2 times/minute ->60 times/minute(including baby) Detection precision of respiration rate: ±1 time/minute
- Standard configuration: ECG, NIBP, SPO2, RESP, PR, Rechargeable Lithium battery Optional: ETCO2 (side stream) Thermal recorder Wall mount Trolley SpO2 Detection scope: 0%-100% Accuracy ±1% 90%-100% ±2% 70%-89% NIBP Theory Electric oscillator Cuff gassing time less than 15 seconds First-time gassing pressure: dynamic state 24kPa(180 mmHg) Manual selection: 9.3kPa(70 mmHg),13.3kPa(100 mmHg),16.0kPa(120 mmHg) 18.6kPa(140 mmHg),20.0kPa(150 mmHg),21.3kPa(160 mmHg), Automatic detection period: 1 minute to 240 minutes Stop size:1 min(1 min -10min), 5min(10 min -30min), 10min(30 m in -90min) and 30min(90 min -240min) Detection scope: Systolic blood pressure: 4kPa -34kPa(30mmHg -255mmHg) Diastolic pressure 2kPa -29.3kPa(15mmHg -220mmHg) Mean pressure 2.7kPa~31.3kPa (20mmHg~235mmHg) Detection accuracy Static pressure: ±3mmHg Pulse rate: ±2%
- ECG Full lead: I, II, III, AVL, AVR, AVF and V Gain: 5mm/mV, 10mm/mV, 15mm/mV, 20mm/mV and 25mm/mV Scanning speed: Changeable with three grades of 12.5mm/s, 25mm/s and 50mm/s Band width: 0.05Hz-100Hz(3dB) Heart rate: Scope: 15 times/minute to 300 times/minutes Accuracy: ±1 time/minute Variation of heart beat LORENZE drawing: Analysis on heart beat data for the current 5 minutes with histogram during RR period. Arrhythmia: Twenty kinds of common abnormal ECG can be analyzed, with ECG data of 1000 times of arrhythmia kept and with 10 seconds kept for each time. Accuracy: Error rate < 20% Undetected rate < 20% ST section Scope: ±0.8mV Precision : < ±0.05mV
Specification:
ECG
Full lead: I, II, III, AVL, AVR, AVF and V
Gain: 5mm/mV, 10mm/mV, 15mm/mV, 20mm/mV and 25mm/mV
Scanning speed: Changeable with three grades of 12.5mm/s, 25mm/s and 50mm/s
Band width: 0.05Hz-100Hz(3dB)
Heart rate:
Scope: 15 times/minute to 300 times/minutes
Accuracy: ±1 time/minute
Variation of heart beat LORENZE drawing: Analysis on heart beat data for the current 5 minutes with histogram during RR period.
Arrhythmia: Twenty kinds of common abnormal ECG can be analyzed, with ECG data of 1000 times of arrhythmia kept and with 10 seconds kept for each time.
Accuracy: Error rate Undetected rate ST section
Scope: ±0.8mV
Precision : < ±0.05mV
SpO2
Detection scope: 0%-100%
Accuracy ±1% 90%-100%
±2% 70%-89%
Notice:
It normally takes around 7-15 business days to USA.
If you wanna more quantity, Just feel free to e-mail to us,we can give you discount. We have lots in stock.