FEATURES: Type "K" Thermocouple Input Switchable Resolution 0.1° / 1° With℃& ℉ switching Max / MIN Function Data Hold Function Room Temperature Compensated T1 & T2 dual points display T1 - T2 differential measurement Flip-up stand Backlight LCD display PECIFICATION: Measuring Rang: - 50 ℃ ~ 1350 ℃ , - 58 ℉ ~ 1999 ℉ Sensor: K Type Thermocouple Input: Single Channel (TES-1311) / Dual Channel (TES-1312A) Resolution: - 50 ℃ ~ 199.9 ℃.....0.1 ℃ , - 50 o F ~ 199.9 ℉.....0.1 ℉ (Others 1 ℃/1 ℉) Accuracy: - 50 ℃ ~ 1000 ℃... +/- (0.3%rdg + 1 ℃) - 50 ℉ ~ 1832 ℉... +/- (0.3%rdg + 2 ℉) 1000 ℃ ~ 1300 ℃... +/- (0.5%rdg + 1 ℃) 1832 ℉ ~ 1999 ℉... +/- (0.5%rdg + 2 ℉) Temperature Coefficient: Less that 0.1 times the applicable accuracy specification per ℃ ( ℉) Input Protection: 60V DC or 24 Vrms AC maximum input voltage on any Combination of input Connector Sampling Rate: 2.5 times/sec Operating / Storage Conditions: 0 ℃ ~ 40 ℃Accessories: Instruction, Manual